New Features:
“Understanding the problem to extend practical solution is something what we have experienced. Their analysis & solution helped Dalmia Cement save recurring energy cost & efficiency in the process to improve quality of our material”
– Dalmia Cements Limited
“Chandak Instruments Pvt. Ltd., Nagpur’s services were utilized to do field study on our combustion air flow measurement. Their systematic approach on the entire process is well appreciated, based on the study carried out we could fine tune the flow meters installed & improve the overall process”
Tata Steel Limited, West Bengal
PARAMETER | PRINCIPLE | RESOLUTION | ACCURACY | RANGE** | STANDARD |
---|---|---|---|---|---|
O2 Oxygen | Electro-chemical cell | 0.1 Vol.% | ± 0.2 Vol. % | 0 – 20.9 Vol. % | |
CO Carbon monoxide | Electro-chemical cell
NDIR |
1 ppm
0.001 Vol.% |
Z | 0 – 2000/4000ppm
0 – 10/20 Vol.% |
NDIR Optional |
NO Nitric oxide | Electro-chemical cell | 1 ppm | Z | 0 – 2000 ppm | |
NO2 Nitrogen dioxide | Electro-chemical cell | 1 ppm | Z | 0 – 100 ppm | |
SO2 Sulfur dioxide | Electro-chemical cell | 1 ppm | Z | 0 – 4000 ppm | |
H2S Hydrogen Sulfide | Electro-chemical cell | 1 ppm | Z | 0 – 200 ppm | |
HC/CH4 Hydrocarbons | Pellistor or NDIR | 0.1 % | Z | 0 – 100% LEL | |
TG Flue gas temperature | NiCr – Ni thermocouple | 1 K | ± 2 % | -4°F – 2192°F
0°C – 1200°C |
|
TA Air temperature | Semiconductor | 1 K | ± 0.2 K | -4°F / 248°F
0°C – 120°C |
|
P Draft | Solid state | 0.01 hPa | ± 2 % | ± 40 hPa | |
NOx Nitrogen oxides | Calculation | 1 ppm | Z | 0 – NOx max | |
CO2 Carbon dioxide | Calculation | 0.1 Vol.% | ± 0.2 Vol. % | 0 – CO2 max | |
CO2 Carbon dioxide | NDIR | 0.01 Vol.% | ± 0.2 Vol. % | 0 – 20 Vol. % | |
NH3 Ammonia | Electro-chemical | 1 ppm | Z | 0 – 1000/5000 ppm | |
N2O Nitrous Oxide | NDIR | 0.001 Vol. % | Z | 0 – 1 Vol. % | |
HCl Hydrogen Chloride | Electro-chemical | 1 ppm | Z | 0 – 200 ppm | |
Cl2 Chlorine | Electro-chemical | 1 ppm | Z | 0 – 5000 ppm | |
H2 Hydrogen | Electro-chemical | 1 ppm | Z | 0 – 10000 ppm | |
Losses / Efficiency | Calculation | 0.1 % | ± 0.1 % | 0 – 99.9 % | |
Excess Air / Lambda | Calculation | 0.1 % | ± 0.1 % | 1.0 – 9.99 | |
Soot | Filter paper method | 0 – 9 | |||
Velocity with Pitot tube | Solid state | 0.01 m/s | ± 2 % | 0 – 80 m/s | |
RPM Meter | Solid state | 100 RPM | ± 2 % | 180 – 10000 RPM | |
** Different/customized ranges available. | Equipped with a maximum of 8 gas sensors |
Z = 0 – 20 % of whole measurement range ± 5 %
21 – 100 % of whole measurement range ± 1 % of displayed measurement
MODEL - IMR 2800 P Dimensions (inch): 15 x 6.5 x 12.4 = (375mm x 165mm x 300mm) Weight: 17 lbs. (8 kg) PART-NO. - IMR 28100