Combustion Gas Analyzer
The IMR1000 is a hand held pocket size stack gas analyzer for combustion tests on boilers, burners, etc. The IMR1000-1/2 has up to two sensors with a 2-line LCD.
Features
- Up to 3 sensors
- Small and rugged
- Easy to operate
- Light weight
- Memory
- Infrared Interface for printer
- Protective boot with integral magnet
- Large backlit display
- Reliable Technology
- Easy to service
- Displayed parameter can be chosen
Measured parameters:
- Oxygen O2
- Carbon Monoxide CO
- Carbon Monoxide CO (ambient)
- Flue-Gas Temperature
Calculated values:
- Combustion Efficiency
- Excess Air
- Carbon Dioxide
- CO corrected to 0% O2
Standard
Enclosure:
Rugged plastic case with protective boot and magnet
Fuels:
Natural Gas, Propane, Butane, LPG, Light Oil
Measuring units:
ppm, mg/m3
Service program:
Check of all values
Zero point calibration:
Max. 60 seconds
Battery:
> 8 hrs
Languages:
English, German, French, etc.
Condensation trap:
Integrated filter
Operating Conditions
32-104°F / 0-40°C;
10-90% rel. humidity, non- condensing
Gas sampling probe:
Thermocouple Type K;
∅ 0.25″/ 6mm; Length 9”/220mm; Hose 9’/3m
Power Supply:
4 x AA
Weight
2.2lbs / 1kg
Dimensions
7.9×1.8×3.5” / 200x45x90mm
Specifications
Features |
IMR1000-1/2 |
Rotary selector |
|
Memory positions (various tests) |
20 |
Infrared printer port |
|
Backlit display |
2 lines |
Boot with integral magnet |
|
User programmable headers |
|
Time & date stamp |
|
1 yr warranty |
|
Temp Measurement |
|
Flue Temp Range |
32 ~ 1112°F / 0 ~ 600°C |
Inlet Temp Range (Ambient) |
32 ~ 1112°F / 0 ~ 600°C |
Net Temp (ΔT)** |
32 ~ 112°F / 0 ~ 50°C |
Resolution |
1°F/°C |
Flue (T1, Inlet T2, & Net ΔT) Accuracy |
±[0.3% rdg +5°F(3°C)] |
Inlet Temp Ambient Accuracy |
±[0.3% rdg +1°F(1°C)] |
Gas Measurement |
|
Oxygen |
0 ~ 21% |
O2 Resolution/Accuracy |
0.1% / ±0.2%* |
Carbon Monoxide |
0 ~ 1000 ppm |
CO Resolution/Accuracy |
1 ppm/±10 ppm < 100 ppm* |
Carbon Dioxide** |
0~30% |
CO2 Resolution/Accuracy |
1.0%/±0.3% reading |
Efficiency** |
0 ~ 99.9% |
Efficiency Resolution/Accuracy |
0.1%/±1.0% reading |
Excess Air** |
0 ~ 250% |
Excess Air Resolution/Accuracy |
0.1%/±0.2% reading |
Pressure (Differential) |
|
|
Range ±0.2mBar 0.08”wg |
|
Range ±1mBar 0.4”wg |
|
Range ±80mBar 32”wg |
Dimensions |
|
Weight |
2.2lbs. with boot |
Handset |
7.9 x 1.8 x 3.5” |
Probe |
11.8 x 0.25 x 9.4” stainless steel shaft,
type K thermocouple (9′ hose) |
Operating temp |
0 to 40°C/10% to 90% Relative Humidity
non-condensing |
Battery |
x4 “AA” cells / 12 hour life typical with
Alkaline “AA” cells |
Warranty |
1 year limited warranty |
Optional
AC adapter with rechargeable batteries
Infrared printer
Soft carrying case
Hard carrying case
1000-1 O2, condensation trap, gas sampling probe, batteries, manual
1000-2 O2, CO, condensation trap, gas sampling probe, batteries, manual