Chandak Instruments Pvt. Ltd.

The Flow Measurement Solution Provider

IMR 1050X

Combustion System Analyzer

IMR_1050X
The newly redesigned IMR 1050X Combustion System Analyzer eliminates the number one hassle for combustion contractors; the annual replacement and calibration of the O2 sensor. By replacing the electro chemical O2 sensor with the EOS Technology™ CO2 sensor, the IMR 1050X now takes direct CO2 measurements and calculates the O2 level. This lowers the cost of ownership by doing away with the annual replacements of the O2 sensor and reducing calibration drifting typically found with standard electro-chemical sensors. The EOS Technology sensor has an unmatched industry leading life expectancy of 10 years!

Features

  • Measures: Differential flue temperature, Carbon Dioxide (CO2), flue &
    ambient carbon monoxide (CO) & Differential Pressure
  • Calculates: oxygen, gross/net efficiency, excess air, & CO air free
  • Worklight
  • 4 line backlit LCD display
  • 179 memory positions
  • User customizable parameters view
  • Individual report printouts
  • Unique DMM style rotary selector
  • Protective boot w/integral magnet
  • Real time clock
  • CO readings to 1 ppm
  • Infrared printer port

Measures, Calculates** or Displays:

  • Oxygen (O2)**
  • Carbon Monoxide (CO)
  • Carbon Dioxide (CO2)
  • Combustion efficiency**
  • Pressure (draft)
  • Date & time
  • Temperature (flue, inlet & net**)
  • Excess air**
  • CO Air Free**
  • Battery level
  • Fuel type
  • Nitric Oxide (IMR 1050X-NO)

IMR 1050X Specifications

Temperature Measurement 1050X 1050X-NO
Flue Temp Range
Inlet Temperature (probe – T2) Inlet

Temperature (ambient)
Net Temperature (_T)**
Resolution

Flue (T1, Inlet T2 & _T) Accuracy
Inlet Temperature Accuracy

20~2400°F (-29~1315°C)
20~2400°F (-29~1315°C)

32~112°F (0~50°C)
20~2400°F (-29~1315°C)
0.1°C/F
±(0.3% rdg
+3.6°F(2°C))
±(0.3% rdg +1.8°F(1°C))

Gas Measurement 1050X 1050X-NO
Oxygen 0~21%** 0~21%**
O2 resolution / accuracy 0.1% / ±0.3% 0.1% / ±0.3%
Carbon Monoxide (CO) 0~2000 ppm (4000 max 15 min)*
CO resolution / accuracy 1ppm / ±10ppm < 100ppm
±5%
rdg > 100ppm
Carbon Dioxide (CO2) 0~20% 0~20%
CO2 Resolution / accuracy 0.1% / ±2% 0.1% / ±2%
Efficiency** 0~99.9%** 0~99.9%**
Efficiency resolution / accuracy 0.1% / ±3% 0.1% / ±3%
Excess Air** 0~250% 0~250%
Excess Air resolution / accuracy 0.1% / ±3% 0.1% / ±3%
CO / CO2 ratio** 0~0.999 0~0.999
CO / CO2 resolution / accuracy 0.001 / ±5% rdg 0.001 / ±5% rdg
Nitric Oxide (NO1) 0~100 ppm
NO1 resolution / accuracy ±5 ppm < 100 ppm
Pressure (Differential) Range Accuracy
  ±0.08” wc (±0.2mBar)
±0.4” wc (±1mBar)
±32”
wc (±80mBar)
±0.002” wc (±0.005mBar)
±0.01” wc
(±0.03mBar)
±3% rdg
Pressure Resolution 0.001” wc < 9.999” wg
0.01”
wc < 10.0” wg
0.001 mBar < 24.999 mBar
0.01 mBar > 25 mBar

* Measured at STP (standard temperature and pressure)

** Calculated value

1050X O2, CO2, CO, draft, Condensation Trap, Flue Probe Particle Filter, Hard Case, Batteries, Quick Start Guide Owner’s Manual
1050X‐NO O2, CO2, CO, NO, draft, Condensation Trap, Flue Probe, Particle Filter, Hard Case, Batteries, Quick Start Guide Owner’s Manual
1050X KIT 1050X Analyzer, Flue Probe, IR Printer, (2) K‐Type Temp Probes, (2) Static Pressure Hoses (1) True Draft Probe, Gas Tap and Hose, AC Adapter/Charger, Hard Case, (2) Printer paper rolls, (2) Particle filters, Batteries, Quick Start Guide, & Owner’s Manual
1050X‐NO KIT 1050X‐NO Analyzer Flue Probe, IR Printer, (2) K‐Type Temp Probes, (2) Static Pressure Hoses, (1) True Draft Probe, Gas Tap and Hose, AC Adapter/Charger, Hard Case, (2) Printer paper rolls, (2) Particle filters, Batteries, Quick Start Guide, & Owner’s Manual

More Details About IMR 1050X

IMR_1050X

COMBUSTION
  • Verify Ambient CO
  • Verity CO Air Free
  • Verify Proper Combustion
  • Verify Combustion Gas, Make Up 02, CO, CO2, Excess Air
  • Verify Stack Loss and Efficiencya

Allows for live fire / real time analysis and trouble shooting, while verifying and documenting needed adjustments, repairs or replacements.

MODULATING & MULTI STAGE SYSTEM SET UP & TESTING:

The IMR 1050X allows the technician to simultaneously set gas pressure while doing a combustion test. Which allows for live fire viewing of combustion gases (over / under fire) while viewing and setting gas pressure to manufacture suggested specifications.

USER PROGRAMMABLE AUXILIARY SCREEN:

The auxiliary screen allows the tech to choose from an assortment of HVAC test parameters they want to view while performing various HVAC applications. This screen also allows a variety of test to be done simultaneously.

Testimonials

“Understanding the problem to extend practical solution is something what we have experienced. Their analysis & solution helped Dalmia Cement save recurring energy cost & efficiency in the process to improve quality of our material”

– Dalmia Cements Limited

“Chandak Instruments Pvt. Ltd., Nagpur’s services were utilized to do field study on our combustion air flow measurement. Their systematic approach on the entire process is well appreciated, based on the study carried out we could fine tune the flow meters installed & improve the overall process”

Tata Steel Limited, West Bengal

1050X KIT
IMR_1050X Kit
1050X-NO KIT
IMR_1050X NO Kit