PARAMETER | PRINCIPLE | RESOLUTION | ACCURACY | RANGE** | STANDARD |
---|---|---|---|---|---|
O2 Oxygen | Electro-chemical cell | 0.1 Vol.% | ± 0.2 Vol. % | 0 – 20.9 Vol. % | |
CO Carbon monoxide | Electro-chemical cell
NDIR |
1 ppm
0.001 Vol.% |
Z | 0 – 2000/4000ppm
0 – 10/20 Vol.% |
NDIR Optional |
NO Nitric oxide | Electro-chemical cell | 1 ppm | Z | 0 – 2000 ppm | |
NO2 Nitrogen dioxide | Electro-chemical cell | 1 ppm | Z | 0 – 100 ppm | |
SO2 Sulfur dioxide | Electro-chemical cell | 1 ppm | Z | 0 – 4000 ppm | |
H2S Hydrogen Sulfide | Electro-chemical cell | 1 ppm | Z | 0 – 200 ppm | |
HC/CH4 Hydrocarbons | Pellistor or NDIR | 0.1 % | Z | 0 – 100% LEL | |
TG Flue gas temperature | NiCr – Ni thermocouple | 1 K | ± 2 % | -4°F – 2192°F
0°C – 1200°C |
|
TA Air temperature | Semiconductor | 1 K | ± 0.2 K | -4°F / 248°F
0°C – 120°C |
|
P Draft | Solid state | 0.01 hPa | ± 2 % | ± 40 hPa | |
NOx Nitrogen oxides | Calculation | 1 ppm | Z | 0 – NOx max | |
CO2 Carbon dioxide | Calculation | 0.1 Vol.% | ± 0.2 Vol. % | 0 – CO2 max | |
CO2 Carbon dioxide | NDIR | 0.01 Vol.% | ± 0.2 Vol. % | 0 – 20 Vol. % | |
NH3 Ammonia | Electro-chemical | 1 ppm | Z | 0 – 1000/5000 ppm | |
N2O Nitrous Oxide | NDIR | 0.001 Vol. % | Z | 0 – 1 Vol. % | |
HCl Hydrogen Chloride | Electro-chemical | 1 ppm | Z | 0 – 200 ppm | |
Cl2 Chlorine | Electro-chemical | 1 ppm | Z | 0 – 5000 ppm | |
H2 Hydrogen | Electro-chemical | 1 ppm | Z | 0 – 10000 ppm | |
Losses / Efficiency | Calculation | 0.1 % | ± 0.1 % | 0 – 99.9 % | |
Excess Air / Lambda | Calculation | 0.1 % | ± 0.1 % | 1.0 – 9.99 | |
Soot | Filter paper method | 0 – 9 | |||
Velocity with Pitot tube | Solid state | 0.01 m/s | ± 2 % | 0 – 80 m/s | |
RPM Meter | Solid state | 100 RPM | ± 2 % | 180 – 10000 RPM | |
** Different/customized ranges available. | Equipped with a maximum of 8 gas sensors |
Z = 0 – 20 % of whole measurement range ± 5 %
21 – 100 % of whole measurement range ± 1 % of displayed measurement
MODEL - IMR 2800 P Dimensions (inch): 15 x 6.5 x 12.4 = (375mm x 165mm x 300mm) Weight: 17 lbs. (8 kg) PART-NO. - IMR 28100